Anti Condensation Heaters
RCE 016 Anti Condensation Heater for Panels
Small heaters designed to prevent condensation and to ensure a minimum operating temperature in small enclosures. The heaters are designed for permanent operation.
|
Part No. | Heating capacity² |
Inrush Current max. |
Surface Temp (approx.) |
01622.0-00 | 5 W | 2.0 A | +165 °C |
01623.0-00 | 9 W | 2.5 A | +175 °C |
RC 016 Anti Condensation Heater for Panels
These small heaters are designed to prevent condensation and to ensure a minimum operating temperature in small enclosures. The heaters are designed for permanent operation.
|
Part No. | Heating capacity² |
Inrush Current max. |
Surface Temp (approx.) |
01602.0-00 | 8 W | 2.0 A | +150 °C |
01609.0-00 | 10 W | 2.5 A | +155 °C |
01610.0-00 | 13 W | 3.0 A | +170 °C |
HGK 047 Anti Condensation Heater for Panels
The heaters are used in enclosures where condensation is to be prevented or the temperature may not fall below a minimum value. In this way corrosion is avoided and an even temperature is ensured. The heaters are designed for permanent operation.
|
Part No. | Operating voltage |
Heating Capacity² |
Inrush Current max. |
04700.0-00 | AC/DC 120 – 240 V² | 10 W | 1.0 A |
04701.0-00 | AC/DC 120 – 240 V² | 20 W | 2.5 A |
04702.0-00 | AC/DC 120 – 240 V² | 30 W | 3.0 A |
04700.9-00 | AC/DC 110 – 120 V | 10 W | 1.0 A |
04701.9-00 | AC/DC 110 – 120 V | 20 W | 1.5 A |
04702.9-00 | AC/DC 110 – 120 V | 30 W | 1.5 A |
HG 140 Anti Condensation Heater for Panels
These heaters are used in enclosures where damage from condensation must be prevented, or where the temperature may not fall below a minimum value. The aluminium profile heater body design has a chimney effect and distributes the heat evenly. The heaters are designed for permanent operation. Pressure clamb connectors save time and simplify installation.
|
Part No. | Heating capacity² |
Inrush current max. |
14000.0-00 | 15 W | 1.5 A |
14001.0-00 | 30 W | 3.0 A |
14003.0-00 | 45 W | 3.5 A |
14005.0-00 | 60 W | 2.5 A |
14006.0-00 | 75 W | 4.0 A |
14007.0-00 | 100 W | 4.5 A |
14008.0-00 | 150 W | 9.0 A |
HV 031 Anti Condensation Fan Heater for Panels
Compact high-performance fan heater prevents formation of condensation and frost and provides an evenly distributed interior air temperature in enclosures with electric/electronic components. This fan heater may only be operated together with a fan but is also available without fan for self-assembly (HV 031) and with pre-configured fan (HVL 031).
|
Part No. HV 031 AC 230 C, 50/60 Hz |
Part No. HV 031 AC 120 V, 50/60 Hz |
Heating capacity |
Recommended pre-fuse T (time-delay) |
|
03100.0-00 | 03100.9-00 | 100 W | 1.0 A - AC 230 V | 2.0 A - AC 120 V |
03101.0-00 | 03101.9-00 | 150 W | 1.25 A - AC 230 V | 2.5 A - AC 120 V |
03110.0-00 | 03110.9-00 | 200 W | 2.0 A - AC 230 V | 3.0 A - AC 120 V |
03111.0-00 | 03111.9-00 | 300 W | 2.0 A - AC 230 V | 4.0 A - AC 120 V |
03112.0-00 | 03112.9-00 | 400 W | 4.0 A - AC 230 V | 6.3 A - AC 120 V |
HGL 046 Anti Condensation Fan Heater for Panels
Compact fan heater prevents formation of condensation and frost. The integrated high-performance axial fan provides an evenly distributed interior air temperature in enclosures with electric/electronic components.
|
Part No. | Operating Voltage |
Heating capacity |
Recommended pre-fuse T (time-delay) |
04640.0-00 | AC 230 V, 50/60 Hz | 250 W | 2.0 A |
04641.0-00 | AC 230 V, 50/60 Hz | 400 W | 4.0 A |
04640.9-00 | AC 120 V, 50/60 Hz | 250 W | 4.0 A |
04641.9-00 | AC 120 V, 50/60 Hz | 400 W | 6.3 A |
CSK 060 Anti Condensation Semiconductor Heater for Panels
The heaters are used in enclosures where condensation is to be prevented or the temperature may not fall below a minimum value. In this way corrosion is avoided and an even temperature is ensured. The heaters are designed for permanent operation.
|
Part No. | Heating capacity² |
Inrush current max. |
Recommended pre-fuse T (time-delay) |
06040.0-00 | 10 W | 1.0 A | 2.0 A |
06030.0-00 | 20 W | 2.5 A | 4.0 A |
CS 060 Anti Condensation Semiconductor Heater for Panels
Touch-safe heater for the use in enclosures with electrical/electronical components. The design of the heater supports the natural convection which results in a high air-current of warm air. The surface temperatures on the accessible side surfaces of the housing are kept down as a result of the heater design. Our complete range of thermostats and hygrostats can directly be connected to the heater CS 060. This heater is also available in a version with plug-in thermostat requiring no additional wiring (CSF 060). The heaters are designed for permanent operation.
|
Part No. | Heating capacity² |
Inrush current max. |
Recommended pre-fuse T (time-delay) |
Air outlet temperature³ |
06000.0-00 | 50 W | 2.5 A | 4.0 A | +86 °C |
06010.0-00 | 100 W | 4.5 A | 8.0 A | +120 °C |
06020.0-00 | 150 W | 8.0 A | 10.0 A | +145 °C |
CSF 060 Anti Condensation Semiconductor Heater for Panels
Touch-safe heater for the use in enclosures with electrical/electronical components. The design of the heater supports the natural convection which results in a high air-current of warm air. The surface temperatures on the accessible side surfaces of the housing are kept down as a result of the heater design. This model with plug-in thermostat does not require additional wiring. The heaters are designed for permanent operation. This heater is also available in a version without thermostat (CS 060).
|
Part No. | Heating capacity² |
Inrush current max. |
Recommended pre-fuse T (time-delay) |
Air outlet temperature³ |
06001.0-00 | 50 W | 2.5 A | 4.0 A | +86 °C |
06002.0-00 | 50 W | 2.5 A | 4.0 A | +86 °C |
06011.0-00 | 100 W | 4.5 A | 8.0 A | +120 °C |
06012.0-00 | 100 W | 4.5 A | 8.0 A | +120 °C |
06021.0-00 | 150 W | 8.0 A | 10.0 A | +145 °C |
06022.0-00 | 150 W | 8.0 A | 10.0 A | +145 °C |
CS 028 Anti Condensation Semiconductor Fan Heater for Panels
Fan heater prevents formation of condensation and provides an evenly distributed interior air temperature in enclosures with electric/electronic components. The heater is connected using the internal terminal connectors. The small size of the CS / CSL 028 makes it ideal for use in enclosures where space is at a premium.
|
Part No. clip fixing |
Part No. screw fixing |
Operating Voltage |
Heating capacity² |
Inrush current max. |
Recommended pre-fuse T (time-delay) |
02800.0-00 | 02800.0-01 | AC 230 V, 50/60 Hz | 150 W | 12.0 A | 10.0 A |
02811.0-00 | 02811.0-01 | AC 230 V, 50/60 Hz | 250 W | 9.0 A | 10.0 A |
02810.0-00 | 02810.0-01 | AC 230 V, 50/60 Hz | 400 W | 15.0 A | 16.0 A |
02800.9-00 | 02800.9-01 | AC 120 V, 50/60 Hz | 150 W | 6.0 A | 10.0 A |
02811.9-00 | 02811.9-01 | AC 120 V, 50/60 Hz | 250 W | 6.0 A | 10.0 A |
02810.9-00 | 02810.9-01 | AC 120 V, 50/60 Hz | 400 W | 9.0 A | 10.0 A |
CR 027 Anti Condensation Semiconductor Fan Heater for Panels
Semiconductor fan heater prevents formation of condensation and frost and provides an evenly distributed interior air temperature in enclosures with electric/electronic components. The integrated thermostat is used to set the desired temperature.
|
Part No. |
Operating Voltage |
Heating capacity¹ (50 Hz) |
Heating capacity¹ (60 Hz) |
Inrush current max. |
Recommended pre-fuse T (time-delay) |
Airflow, free flow |
Setting range thermostat² |
02700.0-00 | AC 220 – 240 V, 50/60 Hz | 475 W | 550 W | 11.0 A | 10.0 A | 35 m³/h | 0 to +60 °C |
02701.0-00 | AC 220 – 240 V, 50/60 Hz | 550 W | 650 W | 13.0 A | 10.0 A | 45 m³/h | 0 to +60 °C |
02700.9-00 | AC 100 – 120 V, 50/60 Hz | 400 W | 550 W | 14.0 A | 10.0 A | 35 m³/h | 0 to +60 °C |
02701.9-00 | AC 100 – 120 V, 50/60 Hz | 510 W | 650 W | 15.0 A | 10.0 A | 45 m³/h | 0 to +60 °C |
CSF 028 Anti Condensation Semiconductor Fan Heater for Panels
The compact fan heater prevents formation of condensation and provides an evenly distributed interior air temperature in enclosures with electric/electronic components. The touch-safe plastic housing and the small dimensions makes it ideal for use in enclosures with high packing density. The CSF 028 is equipped with a preset thermostat. It is connected via external clamps. The fan heater is available with two different mounting systems – either mounting by screw flange or by clip. The robust screw flange fixing is particularly suitable for applications with high vibration.
|
Part No. clip fixing |
Part No. screw flange fixing |
Operating Voltage |
Heating capacity¹ |
Inrush current max. |
Recommended pre-fuse T (time-delay) |
Switch-off temperature² |
Switch-on temperature² |
02821.0-06 | 02821.0-08 | AC 230 V, 50/60 Hz | 250 W | 9.0 A | 10.0 A | +15 °C | +5 °C |
02821.0-09 | 02821.0-11 | AC 230 V, 50/60 Hz | 250 W | 9.0 A | 10.0 A | +25 °C | +15 °C |
02820.0-06 | 02820.0-08 | AC 230 V, 50/60 Hz | 400 W | 15.0 A | 16.0 A | +15 °C | +5 °C |
02820.0-09 | 02820.0-11 | AC 230 V, 50/60 Hz | 400 W | 15.0 A | 16.0 A | +25 °C | +15 °C |
02821.9-06 | 02821.9-08 | AC 120 V, 50/60 Hz | 250 W | 6.0 A | 10.0 A | +15 °C | +5 °C |
02821.9-09 | 02821.9-11 | AC 120 V, 50/60 Hz | 250 W | 6.0 A | 10.0 A | +25 °C | +15 °C |
02820.9-06 | 02820.9-08 | AC 120 V, 50/60 Hz | 400 W | 9.0 A | 10.0 A | +15 °C | +5 °C |
02820.9-09 | 02820.9-11 | AC 120 V, 50/60 Hz | 400 W | 9.0 A | 10.0 A | +25 °C | +15 °C |
HVI 030 Anti Condensation Fan Heater for Panels
The compact high-performance fan heater prevents formation of condensation and frost and provides an evenly distributed interior air temperature in enclosures with electric/electronic components. The heater may only be operated together with fan, but is also available without axial fan (for self-installation). The fan heaters are available with two different mounting systems – either mounting by screw fixing or with a new and unique twist clip mounting system. These options allow for a quick and easy installation of the fan heater.
|
Part No. twist clip fixing |
Part No. screw fixing |
Operating Voltage |
Heating capacity |
Recommended pre-fuse T (time-delay) |
03074.0-00 | 03074.0-01 | AC 230 V, 50/60 Hz | 500 W | 4.0 A |
03073.0-00 | 03073.0-01 | AC 230 V, 50/60 Hz | 600 W | 4.0 A |
03072.0-00 | 03072.0-01 | AC 230 V, 50/60 Hz | 700 W | 6.3 A |
03074.9-00 | 03074.9-01 | AC 120 V, 50/60 Hz | 500 W | 8.0 A |
03073.9-00 | 03073.9-01 | AC 120 V, 50/60 Hz | 600 W | 8.0 A |
03072.9-00 | 03072.9-01 | AC 120 V, 50/60 Hz | 700 W | 10.0 A |
CR 030 Anti Condensation Fan Heater for Panels
The compact high performance fan heater prevents formation of condensation and frost and provides an evenly distributed interior air temperature in enclosures with electric/electronic components. The plastic housing provides double insulation and acts as protection against contact. The fan heater is available with integrated thermostat or pre-set hygrostat for temperature or humidity control. The CR 030 was designed as a stationary unit for the bottom of the enclosure. For wall fixing the fan heater CR 130 is recommended.
|
Part No. |
Model |
Operating Voltage |
Heating capacity |
Recommended pre-fuse T (time-delay) |
03051.0-00 | Fan Heater with thermostat | AC 230 V, 50/60 Hz | 950 W | 6.3 A |
03051.0-02 | Fan Heater with hygrostat | AC 230 V, 50/60 Hz | 950 W | 6.3 A |
03059.9-00 | Fan Heater with thermostat | AC 120 V, 50/60 Hz | 950 W | 10.0 A |
CR 130 Anti Condensation Fan Heater for Panels
The compact high performance fan heater prevents formation of condensation and frost and provides an evenly distributed interior air temperature in enclosures with electric/electronic components. The plastic housing provides double insulation and acts as protection against contact. The fan heater is available with integrated thermostat or pre-set hygrostat for temperature or humidity control. The CR 130 was designed as a stationary unit for wall fixing. For fixing on the bottom of the enclosure the fan heater CR 030 is recommended.
|
Part No. |
Model |
Operating Voltage |
Heating capacity |
Recommended pre-fuse T (time-delay) |
13051.0-00 | Fan Heater with thermostat | AC 230 V, 50/60 Hz | 950 W | 6.3 A |
13051.0-02 | Fan Heater with hygrostat | AC 230 V, 50/60 Hz | 950 W | 6.3 A |
13059.9-00 | Fan Heater with thermostat | AC 120 V, 50/60 Hz | 950 W | 10.0 A |
DCR 030 Anti Condensation Fan Heater for Panels
The compact high performance fan heater prevents formation of condensation and frost and provides an evenly distributed interior air temperature in enclosures with electric/electronic components. The fan heater is available with an integrated electronic thermostat or integrated electronic hygrostat. The model with thermostat is available with internal or external sensor. The fan heater with integrated hygrostat is equipped with an external sensor. The external sensor can be positioned freely anywhere in the enclosure for precise measurements of temperature and humidity. The DCR 030 was designed as a stationary unit for the bottom of the enclosure. For wall fixing the fan heater DCR 130 is recommended.
|
Part No. |
Model |
Operating Voltage |
Heating capacity |
Recommended pre-fuse T (time-delay) |
03092.1-12 | Thermostat with internal sensor | DC 24 V | 200 W | 25.0 A |
03092.1-13 | Thermostat with connector for external sensor² | DC 24 V | 200 W | 25.0 A |
03097.3-12 | Thermostat with internal sensor | DC 56 V | 800 W | 25.0 A |
03097.3-13 | Thermostat with connector for external sensor² | DC 56 V | 800 W | 25.0 A |
03092.1-03 | Hygrostat with connector for external sensor² | DC 24 V | 200 W | 25.0 A |
03095.3-03 | Hygrostat with connector for external sensor² | DC 56 V | 600 W | 25.0 A |
DCR 130 Anti Condensation Fan Heater for Panels
The compact high performance fan heater prevents formation of condensation and frost and provides an evenly distributed interior air temperature in enclosures with electric/electronic components. The fan heater is available with an integrated electronic thermostat or electronic hygrostat. The model with thermostat is available with internal or external sensor. The fan heater with integrated hygrostat is equipped with an external sensor. The external sensor can be positioned freely anywhere in the enclosure for precise measurements of temperature and humidity. The DCR 130 was designed for wall fixing. For fixing on the bottom of the enclosure the fan heater DCR 030 is recommended.
|
Part No. |
Model |
Operating Voltage |
Heating capacity |
Recommended pre-fuse T (time-delay) |
13092.1-12 | Thermostat with internal sensor | DC 24 V | 200 W | 25.0 A |
13092.1-13 | Thermostat with connector for external sensor² | DC 24 V | 200 W | 25.0 A |
13097.3-12 | Thermostat with internal sensor | DC 56 V | 800 W | 25.0 A |
13097.3-13 | Thermostat with connector for external sensor² | DC 56 V | 800 W | 25.0 A |
13092.1-03 | Hygrostat with connector for external sensor² | DC 24 V | 200 W | 25.0 A |
13095.3-03 | Hygrostat with connector for external sensor² | DC 56 V | 600 W | 25.0 A |
CS 032 Anti Condensation Semiconductor Fan Heater for Panels
The compact high performance fan heater prevents formation of condensation and frost and provides an evenly distributed interior air temperature in enclosures with electric/electronic components. The plastic housing provides double insulation and acts as protection against contact. Two screw connectors at the front of CS 032 allow comfortable wiring of an external thermostat. The CSF 032 is equipped with a pre-set thermostat. Both models were designed for wall fixing. A fan heater for fixing on the bottom of the enclosure is available on request.
|
Part No. (With Thermostat) Clip fixing |
Part No. (With Thermostat) Screw fixing |
Operating Voltage |
Heating capacity¹ |
Inrush current max. |
03209.0-00 | 03209.0-01 | AC 220 – 240 V, 50/60 Hz | 1000 W | 12.0 A |
03209.9-00 | 03209.9-01 | AC 100 – 120 V, 50/60 Hz | 1000 W | 18.0 A |
Part No. (Without Thermostat) Clip fixing |
Part No. (Without Thermostat) Screw fixing |
Operating Voltage |
Heating capacity¹ |
Inrush current max. |
03201.0-00 | 03201.0-01 | AC 220 – 240 V, 50/60 Hz | 1000 W | 12.0 A |
03202.0-00 | 03202.0-01 | AC 220 – 240 V, 50/60 Hz | 1000 W | 12.0 A |
03201.9-00 | 03201.9-01 | AC 100 – 120 V, 50/60 Hz | 1000 W | 18.0 A |
03202.9-00 | 03202.9-01 | AC 100 – 120 V, 50/60 Hz | 1000 W | 18.0 A |
CS 030 Anti Condensation Semiconductor Fan Heater for Panels
The compact high performance fan heater prevents formation of condensation and frost and provides an evenly distributed interior air temperature in enclosures with electric/electronic components. The plastic housing provides double insulation and acts as protection against contact. The fan heater is available with optional integrated thermostat for temperature control. The CS 030 was designed as a stationary unit for the bottom of the enclosure. For wall fixing the fan heater CS 130 is recommended.
|
Part No. |
Model |
Operating Voltage |
Heating capacity¹ |
Inrush current max. |
Recommended pre-fuse T (time-delay) |
03060.0-00 | Fan Heater with thermostat | AC 230 V, 50/60 Hz | 1200 W | 13.0 A | 10.0A |
03060.0-01 | Fan Heater without thermostat | AC 230 V, 50/60 Hz | 1200 W | 13.0 A | 10.0A |
03060.9-00 | Fan Heater with thermostat | AC 120 V, 50/60 Hz | 1200 W | 16.0 A | 16.0A |
03060.9-01 | Fan Heater without thermostat | AC 120 V, 50/60 Hz | 1200 W | 16.0 A | 16.0A |
CS 130 Anti Condensation Semiconductor Fan Heater for Panels
The compact high performance fan heater prevents formation of condensation and frost and provides an evenly distributed interior air temperature in enclosures with electric/electronic components. The plastic housing provides double insulation and acts as protection against contact. The fan heater is available with optional integrated thermostat for temperature control. The CS 130 was designed as a stationary unit for wall fixing. For fixing on the bottom of the enclosure the fan heater CS 030 is recommended.
|
Part No. |
Model |
Operating Voltage |
Heating capacity¹ |
Inrush current max. |
Recommended pre-fuse T (time-delay) |
13060.0-00 | Fan Heater with thermostat | AC 230 V, 50/60 Hz | 1200 W | 13.0 A | 10.0A |
13060.0-01 | Fan Heater without thermostat | AC 230 V, 50/60 Hz | 1200 W | 13.0 A | 10.0A |
13060.9-00 | Fan Heater with thermostat | AC 120 V, 50/60 Hz | 1200 W | 16.0 A | 16.0A |
13060.9-01 | Fan Heater without thermostat | AC 120 V, 50/60 Hz | 1200 W | 16.0 A | 16.0A |
Visit Stego Anti Condensation Heaters for more information