Laser Measurement

Laser Non Contact Measurement - ODS Blackline

dse ODS black line non contact laser measurement

Short description:

  • Static measurement on white paper at measuring/sampling frequency, without any averaging of the serial output signal: 2·б » 2 times the standard deviation.
  • Analog output Resolution: 14 Bit DAC’s are used for the conversion of the 18 bit digital distance result, an integer value with a nominal resolution of 0.01 mm.
  • Serial/Digital and Analog output are updated at the measuring frequency of 2 kHz/10 kHz except if the Simple Average Filter is activated.
  • 10kHz measuring frequency requires RS422, Ethernet is a Serial Interface option for distance measurement.
  • Laser class IEC 3R may be needed for some HT and VHT sensor versions

Analog output: 4-20 mA or 1-9 V
Digital output: RS232 or RS422
Baud rate: 115200 for 2 kHz outputfrequency
Baud rate: 460800 for10 kHz outputfrequency

Download Brochure
Download Product Specifications

Get a Quote


Laser Non Contatct Measurement - ODS Greyline

dse grey line non contact laser measurement

Short Description:

  • Static measurement on white paper at measuring/sampling frequency, without any averaging of the serial output signal: 2·б » 2 times the standard deviation.
  • Analog output Resolution: 14 Bit DAC’s are used for the conversion of the 18 bit digital distance result, an integer value with a nominal resolution of 0.001 mm.
  • Serial/Digital and Analog output are updated at the measuring frequency of 2 kHz & 10 kHz except if the Simple Average Filter is activated.
  • Ethernet is a Serial Interface option for distance measurement.
  • Laser class IEC 3R may be needed for some HT and VHT sensors versions.

Analog output: 4-20 mA or 1-9 V
Digital output: RS232 or RS422
Baud rate: 115200 for: 2 kHz output frequency
Baud rate: 38400 for: 1 kHz output frequency

Download Brochure
Download Product Specifications

Get a Quote


Laser Non Contact Measurement ODS Redline

dse red line laser non contact measurement

Short description:

  • Static measurement on white paper at measuring frequency of 1 kHz, without any averaging of the output signals. Sampling and output frequency being equal.
  • Data are for digital as well as analog outputs, because 14 Bit DAC’s are used for the conversion.
  • The serial/digital and analog outputs are updated at the measuring frequency of 1 kHz except if the Simple Average Filter is set to be active.
  • The Ethernet interface can be used for distance measurement only, i.e. connection for sensor internal thickness or difference measurement is not available.

Analog output: 4-20 mA or 1-9 V DC
Digital output: RS232 or RS422
Ethernet output: Alternative to RS output
Baud rate: 38400 1 kHz output frequency

Download Brochure
Download Product Specifications

Get a Quote


Visit DSE Laser Maesurement for more information